It is essential that fire alarm systems be regularly serviced. This needs to be done in the following manner: Daily Housekeeping The end user must ensure at all times that all smoke detectors are clear of obstructions. Proper   precautions   must   be   taken   to   prevent   contamination   of   detectors   and   to   avoid   false   alarms   in   areas   that would create dust, smoke, spray paint etc. All temporary protective covers are removed, when such work is completed. All trouble or fault conditions indicated by the panel are investigated and rectified immediately if possible.   Weekly Tests Each   week   a   device   on   a   different   zone   must   be   tested   to   ensure   that   the   zone,   the   panel   and   the   communication   to   the   devices   are   in   proper working order. The fire department should be warned in advance of all tests. Fuel, oil and coolant levels of any emergency generators must be tested and topped up as required. All printers attached to the system must be checked for ink and paper for at least 2 weeks normal usage. All defects must be recorded in the log book and rectified immediately. Monthly Tests Any emergency generators must be started and run for at least ten minutes. The generator must be loaded up to at least 50% for this time, before fuel levels are topped up. Quarterly Tests (Must be done by an Approved Installer) All log book entries checked, and corrected. Batteries tested as per manufacturer requirements. All   detectors,   removed,   cleaned   and   put   back   in   position.   In   sympathetic   environments,   it   is   often   the   practice   with   large   systems   to   carry   out this process on a rotational basis doing 25% or 50% at each service so that all are serviced within a defined time span. All zones are to be fully tested. All fault condition indicators are to be tested. All equipment must be checked for signs of deterioration. The site must be inspected to ensure that all areas requiring protection are covered and that all detectors are free from obstruction. Any further checks required by the manufacturer or local authorities are carried out. The logbook and certificate of testing is completed. Annual   Tests   (Must   be   done   by   an   Approved   Installer   -   F.A.C.N   is   an   approved   Gauteng   Fire   Alarm   Service Provider and Installer) All of the above tests are carried out. All equipment and cable fittings are tested to ensure that they are securely mounted. The logbook and certificate of testing is completed.  Recent Projects Completed By Your   Number One Gauteng Fire Alarm System Provider : Velmore Hotel Group Protea Hotel Hatfield Royal Elephant Hotel Austrian Embassy TUT Witbank Campus SAPS GEMS Siemens Mozambique Murray & Robberts M&T Development Net One Limited Zambia Government Printers We are your one-stop GAUTENG FIRE ALARM service provider
F
A
C
N
Telephone:  +27(0) 12 348 4333
    Cellular:  +27(0) 83 609 3729
Fire Detection Systems
Access Control Systems
CCTV and Public Address Systems
Network and Data Installations
Nurse Call Systems Wireless

GAUTENG FIRE ALARM SYSTEM SERVICES

FIRE ALARM SYSTEMS
PRODUCTS
CCTV | Fire | Access | Nurse Call
ON-LINE CONTACT FORM
Quotation and enquiries
gauteng fire alarm system gauteng fire alarm services

& MAINTENANCE

© F.A.C.N 2013 - 2017